Collect the sample without sending people to the sampling point.
Speedip V2+ carries physical water sampling to difficult-access locations, lowers the container to a defined depth and brings the sample back for laboratory analysis.
Reach the point. Control the depth. Keep the sample.
Aerial physical sampling can range from improvised containers to purpose-built systems. Speedip complements—not replaces—laboratory analysis by making sample collection safer, more repeatable and less constrained by shoreline access.
Do not leave the point unmeasured
Move the sampler to the location, not the team.
Use the UAV to reach target points across steep banks, remote shores and other difficult terrain while the operating team remains on stable ground.
Speedip contribution
Remote access to a physical sample
Operational value
Broader sampling coverage with less terrain dependence
Reduce time on the water
Collect remotely where boat access is disproportionate.
For suitable missions, Speedip can reduce launch preparation, travel and retrieval work while keeping people away from hazardous or uncomfortable water conditions.
Speedip contribution
Fast aerial deployment and retrieval
Operational value
Less personnel exposure and faster response
Keep the sampling plan flexible
Move between points without installing fixed infrastructure.
Repeat known waypoints or respond to a new location without committing to a permanent collection system at every point.
Speedip contribution
Waypoint-based repeat sampling
Operational value
Lower setup commitment and adaptable coverage
Use a purpose-built sampling system
Control the rope, container and sampling sequence.
Speedip adds fixed-depth logic, real-time rope monitoring, automatic retrieval and a purpose-designed container connection to a task that is difficult to standardise with a loose bucket and rope.
Speedip contribution
Integrated control and failure protection
Operational value
More repeatable sampling and safer flight handling
Applications
One sampling system. Different reasons to collect.
Start with the waterbody, required sample integrity and decisions that will be made after laboratory analysis.
01
Routine water sampling
Repeat collection at defined locations and depths for ongoing environmental or operational programmes.
Rivers · lakes · reservoirs · coastal water
02
Environmental investigation
Collect physical evidence from selected points during pollution investigations, incident assessment or compliance work.
Reach selected points quickly when access conditions or possible contamination make direct collection undesirable.
Incident response · wastewater · industrial or mining ponds
A repeatable field workflow
From waypoint to physical sample in four steps.
Automatic operation handles the controlled lowering and retrieval. Semi-automatic and manual modes remain available for selected field conditions.
01
Install
Mount Speedip, secure the integration and confirm communication with the aircraft.
02
Position
Fly to the target, hover above the surface and set the required sampling depth.
03
Sample
Automatically lower the container, collect at depth and monitor system status.
04
Retrieve
Return the aircraft, detach the container and transfer the physical sample.
Speedip V2+ system
Purpose-built around the sampling sequence.
The main unit, range sensing, rope management, controller integration and containers work as one field system.
01
Defined-depth logic
Millimetre-wave ranging and intelligent control calculate the lowering distance from the aircraft's position above the water.
02
Situational awareness
A starlight-level downward-facing camera provides a wide view of the operating area during remote sampling.
03
Rope protection
Real-time monitoring detects tangling, backwinding and bottom contact, with an emergency rope-release function available.
04
Controller workflow
Compatible DJI aircraft provide sampling status and control through the pilot interface, including waypoint-based operations.
05
Fast field setup
The product is designed for rapid mounting and removal, automatic lid operation and single-handed container changes.
06
Health management
System alerts and cumulative winch records support maintenance planning and more dependable repeat operation.
< 750 gMain-unit weight
10 mInstalled rope length
< 20 secDesigned mounting or removal time
USB-C APIAvailable for selected non-DJI integrations
Operating boundary: achievable sampling depth equals the installed rope length minus the UAV's hover height above the surface. Speedip collects physical samples; it does not analyse water quality in the field. Rain operation is not recommended.
Platforms, packages and pricing
Choose the aircraft, then the complete package.
DJI Matrice 400 and DJI Matrice 350 / 300 use purpose-built Speedip models and integration kits. Select general-purpose or PFAS-ready containers after choosing the aircraft.
DJI Matrice 400
Dedicated M400 main unit with corresponding integration kit
2 L PMMA container in standard package
DJI Pilot 2 control and waypoint workflow
DJI Matrice 350 / 300
Dedicated M350 / M300 main unit with corresponding integration kit
1 L PMMA container in standard package
DJI Pilot 2 control and waypoint workflow
Compare what is included, not only the main unit.
Prices below exclude the UAV and applicable delivery or import costs.
Aircraft platform
Standard package
PFAS-ready package
DJI Matrice 400Dedicated M400 Speedip model
General-purpose sampling
USD 5,700
M400 main unit with corresponding integration kit ×1
2 L PMMA container ×1
PFAS-focused and general sampling
USD 6,600
Everything in Standard
Stainless-steel container ×3
DJI Matrice 350 / 300Dedicated M350 / M300 Speedip model
General-purpose sampling
USD 5,250
M350 / M300 main unit with corresponding integration kit ×1
1 L PMMA container ×1
PFAS-focused and general sampling
USD 6,150
Everything in Standard
Stainless-steel container ×3
Quality and sample integrity
Designed for repeat use, not as a one-off modification.
Product and container controls address the two things that matter after access is solved: dependable operation and confidence in the collected sample.
01
Material control
Container materials, cleanliness, sealing and packing are controlled around the sampling application.
02
PFAS validation
Stainless-steel containers undergo third-party leaching and adsorption testing for PFAS-sensitive work.
03
Unit-level testing
In-process inspection, load testing and real-flight sampling checks are completed before shipment.
Frequently asked questions
Confirm the waterbody, depth, container and aircraft.
The correct configuration depends on the sampling purpose, required material controls and the platform available to the field team.
What is Speedip V2+ designed to do?
Speedip V2+ is designed to collect physical water samples at selected locations and depths using a UAV. The samples are returned for established laboratory or downstream analytical methods.
How deep can Speedip sample?
The installed rope is 10 metres. The maximum achievable sampling depth is the rope length minus the UAV's hover height above the surface. For example, a one-metre hover height permits a theoretical maximum depth of about nine metres.
Does Speedip analyse water quality?
No. Speedip collects and retrieves the physical sample. It does not measure water-quality parameters or replace laboratory analysis.
What is the difference between Standard and PFAS-ready packages?
The Standard package uses a PMMA container for general-purpose sampling. The PFAS-ready package adds three validated stainless-steel containers for PFAS-sensitive work while remaining usable for general sampling.
Which UAVs are supported?
Native configurations are available for DJI Matrice 400 and DJI Matrice 350 / 300. Selected non-DJI aircraft can integrate through the USB-C API after AIRINS confirms mounting space, payload and platform suitability.
Is the UAV included in the listed price?
No. The pricing covers the applicable Speedip main unit, container and integration kit. The aircraft, freight, taxes, tariffs, insurance and other applicable fees are separate.
How should containers be handled between locations?
Containers should be cleaned according to the sampling programme and analytical requirements before reuse. Separate containers may be appropriate where cross-contamination is a critical concern.
What support and maintenance are available?
Remote support is included. On-site support can be arranged separately. The Health Management System tracks cumulative winch operation, with factory maintenance recommended when the system indicates the service interval.