Township pipeline and through-window methane detection tests in Hebei
Belt Scan and fine attitude adjustments were used to test township pipelines and through-window methane detection despite complex building facades and obstruction by trees.

The challenge
The township pipeline test was conducted in windy conditions, with complex building facades and obstruction by trees.
What AIRINS deployed
Belt Scan and fine attitude adjustments were used to inspect two simulated valve leaks after optimising the flight parameters.
What happened
Both simulated leaks were detected, giving a 100% leak detection rate in this test, with clear alarms. AI hotspot identification was then used for localisation.
Why it mattered
Different glass types on a multi-storey building were tested individually, and indoor methane was successfully detected.
MetScan V1 | Field experience with township gas inspection and through-window methane detection in Hebei. 📝 During the township pipeline test, we combined Belt Scan with fine attitude adjustments to achieve full coverage despite complex building facades and obstruction by trees. Two valve leaks were simulated in windy conditions. After optimising the flight parameters, both leaks were detected, giving a 100% leak detection rate in this test, with clear alarms. Methane was also detected in parts of the farmland. AI hotspot identification enabled precise localisation of the measurements, validating MetScan V1's reliability and performance in windy conditions in this complex rural setting. The through-window tests checked different glass types on a multi-storey building individually. Indoor methane was successfully detected, earning strong recognition from the user.
Interested?
Discuss your application
Tell us about your application, operating conditions and the results you need.