CONFIGURABLE GAS SENSING

In-situ gas sensing and mapping, from air to ground

Sniffer4D combines configurable hardware, flexible deployment and AIRINS.ai software for air-pollution mapping, hazardous gas monitoring and application-specific plume measurements.

  • Multi-gas sensing
  • Aerial & ground deployment
  • 2D & 3D mapping
ConfigureDeployMapReport

Applications

Gas sensing for safety, emissions and air quality.

Sniffer4D combines in-situ measurements, spatial mapping and application-specific analysis. Select a field task to explore the deployment, sensing configuration and outputs your team can obtain.

Industrial sites & emergency response

Assess gas conditions before moving closer.

Map selected hazardous gases around industrial sites and incident areas, with georeferenced concentration maps to support routine monitoring and emergency response.

Typical deployment
UAV or quadruped robot
Typical output
Live visual alarm and live map
Typical sensing configuration
HAZMAT Multi-Gas · one high-range combustible-hydrocarbon sensor (alkanes) + four incident-specific modules, commonly TVOC, CO, H₂S, NH₃
Discuss hazardous gas monitoring

One connected workflow

Configure, deploy, analyse and act.

The hardware, platform integration and AIRINS.ai stay connected from mission setup to the final operational record.

  1. 01

    Configure

    Select the sensing modules and platform for the application.

  2. 02

    Deploy

    Operate from an aerial, dock-based or ground platform.

  3. 03

    Analyse

    Review georeferenced measurements and spatial patterns.

  4. 04

    Act

    Export reports, data and mission records for follow-up.

Deployment options

Bring the same sensing logic to different platforms.

Choose around coverage, automation, access and the aircraft or vehicle already available to the operating team.

Repeatable autonomous coverage

Build routine measurement into a dock-based operation.

Suitable where the same area or route must be revisited consistently with minimal on-site setup.

DJI Pilot 2 and FlightHub 2 workflow

Sniffer4D configurations

Choose multi-gas flexibility or dedicated methane sensing.

Both configurations use the same connected deployment and AIRINS.ai workflow, while the sensing architecture is selected around the application.

Configurable sensing

Sniffer4D Nano 2 Plus
Multi-Gas

Five internal slots support sensing modules selected for environmental, industrial or emergency applications.

  • Five internal sensing-module slots
  • Application-specific parameter combinations
  • AIRINS.ai mapping and reporting
Explore sensing specifications

Dedicated methane-only sensing

Sniffer4D Nano 2 Plus
Methane

Dedicated multi-pass TDLAS sensing for in-situ methane concentration measurements and spatial plume mapping.

  • 0–11,000 ppm linear range
  • 200 ppb limit of detection
Discuss a methane configuration

Multi-Gas sensing modules

Compare Multi-Gas module specifications.

This table applies only to Sniffer4D Nano 2 Plus Multi-Gas. Sniffer4D Nano 2 Plus Methane uses a separate dedicated sensing architecture; its specifications are shown in the configuration card above.

5 slots totalMulti-Gas capacity
1 slot eachMost modules
Uses all 5TSP / PM100
Sensor
module
Slots
required
Sensing
principle
Linear
range
Limit of
detection
Display
resolution
PM1.0 / PM2.5 / PM101Light scattering5–1,000 µg/m³5 µg/m³1 µg/m³
O₃ + NO₂1Electrochemistry0–11 ppm10 ppb1 ppb
NO₂1Electrochemistry0–11 ppm10 ppb1 ppb
CO1Electrochemistry0–11 ppm0.05 ppm0.005 ppm
TVOC1PID0–50 ppm (isobutylene)0.02 ppm0.01 ppm
H₂S1Electrochemistry0–90 ppm0.03 ppm0.01 ppm
NH₃1Electrochemistry0–100 ppm1 ppm0.1 ppm
Odour indicationH₂S-equivalent; indicative, not olfactometric1Electrochemistry0–10 ppm H₂S-eq.0.1 ppm H₂S-eq.0.01 ppm H₂S-eq.
TSP / PM1005Light scattering30–3,000 µg/m³50 µg/m³1 µg/m³
SO₂1Electrochemistry0–15 ppm0.03 ppm0.005 ppm
HCHO1Electrochemistry0–100 ppm1 ppm0.1 ppm
High-range combustible hydrocarbonsResponds to methane and other alkanes; readings reported as CH₄-equivalent.1NDIR0–5% vol CH₄-eq.—0.01% vol CH₄-eq.
For high-concentration indication only
Need an exact combination?

Tell AIRINS the target gases, expected range, platform and operating environment. We will recommend a compatible configuration.

Discuss the parameters

What the team receives

Mapped gas intelligence—not a loose sensor file.

Select an output to see how AIRINS.ai carries a Sniffer4D mission into review, reporting and follow-up.

Live mission view
Measurements connected to position

Review current readings in their geographic and mission context while the operation is underway.

From the field

Evidence across different operating jobs.

See how Sniffer4D connects the deployed configuration, measurement context and practical result across environmental, industrial and methane-survey work.

Flare-stack inspection in Indonesia
01Indonesia

With Halo Robotics

Flare-stack inspection in Indonesia

Two sensing payloads surveyed different flare-stack sections for an oil and gas operator.

2
Complementary payloads
Forward
Methane sensing
Read more
Environmental research support in Texas
02Texas, USA

With University research group; unnamed

Environmental research support in Texas

AIRINS supported researchers already using Sniffer4D, combining calibration assistance with tests in two environmental settings.

2
Sniffer4D models
Lake
Campus test setting
Read more
Emergency-response demonstration in Alicante
03Alicante, Spain

With ACRE; Ayuntamiento de Alicante firefighters

Emergency-response demonstration in Alicante

Show how airborne gas observations can support emergency response.

Read more

Commercial model

Configure once. Purchase the selected system.

Sniffer4D is supplied through a one-time purchase. AIRINS quotes the configuration after confirming the required sensing modules, platform and integration accessories.

01 · Sensor configuration

Select the measurements the job requires.

The price is determined by the chosen internal sensing modules and whether the configuration is multi-gas or dedicated to methane.

02 · Platform integration

Match the system to the deployment.

The quotation includes the applicable DJI or platform-agnostic integration kit, mounting and any selected field accessories.

  • One-time purchase; exact quotation by configuration
  • Standard one-year product warranty included
  • AIRINS.ai Private Deployment available as a separately priced add-on; first-year support and updates included, with annual renewal thereafter
  • Shipping, taxes, duties and local installation excluded
  • Distributor pricing may reflect local costs
  • Standard configurations normally ship within one week after payment
  1. 01 Discuss the configuration
  2. 02 Receive quotation and invoice
  3. 03 Pay and prepare shipment

Frequently asked questions

Choose around the mission, not only the sensor list.

Configuration depends on the target gases, aircraft or vehicle, operating environment and required output.

How do Sniffer4D and MetScan differ?

Sniffer4D provides in-situ gas measurements for spatial mapping and application-specific assessments. MetScan focuses on remote methane screening and source localisation, with SRQ available through eligible configurations. AIRINS recommends the sensing approach around the measurement objective, access conditions and required output.

Can Sniffer4D be integrated with non-DJI UAVs?

Yes. The Sniffer4D Platform Agnostic Integration Kit provides its own GNSS and power-management system. The host platform needs to provide 12–60 V DC power.

Can one aircraft carry two Sniffer4D units?

DJI Matrice 400 and DJI Matrice 350 / 300 configurations can include a dual-Sniffer setup when the application and aircraft configuration require it.

How are sensing modules selected?

AIRINS selects compatible module combinations around target gases, expected concentration ranges, environmental conditions and the available internal slots.

What can be delivered after a mission?

AIRINS.ai supports georeferenced measurements, 2D and 3D visualisations, reports, mission records and common GIS or tabular exports.

What is the high-range combustible hydrocarbon module for?

It adds a one-slot, high-range CH₄-equivalent sensor to a HAZMAT Multi-Gas configuration. The other four slots are selected for the incident, commonly covering TVOC, CO, H₂S, SO₂ or NO₂. It is intended only to indicate high combustible-hydrocarbon concentrations—not to measure ambient methane or GHG emissions—and does not replace certified personal or fixed-area gas-safety instruments.

Can Sniffer4D deliver flare-efficiency and marine methane-slip assessments?

Yes. AIRINS provides validated, application-specific measurement and analysis workflows for both tasks. The sensing configuration, sampling procedure, assessment method and deliverables are agreed for the selected application.

Configure the field workflow

Tell us what you need to measure and where.

Share the target gases, platform, operating environment and required output. AIRINS will recommend a Sniffer4D configuration.

Submit the configuration brief below ↓