In-situ gas sensing and mapping, from air to ground
Sniffer4D combines configurable hardware, flexible deployment and AIRINS.ai software for air-pollution mapping, hazardous gas monitoring and application-specific plume measurements.
Gas sensing for safety, emissions and air quality.
Sniffer4D combines in-situ measurements, spatial mapping and application-specific analysis. Select a field task to explore the deployment, sensing configuration and outputs your team can obtain.
Industrial sites & emergency response
Assess gas conditions before moving closer.
Map selected hazardous gases around industrial sites and incident areas, with georeferenced concentration maps to support routine monitoring and emergency response.
Typical deployment
UAV or quadruped robot
Typical output
Live visual alarm and live map
Typical sensing configuration
HAZMAT Multi-Gas · one high-range combustible-hydrocarbon sensor (alkanes) + four incident-specific modules, commonly TVOC, CO, H₂S, NH₃
Map particulate matter and selected gases across sites, boundaries and survey routes. Compare concentrations between locations and repeated surveys, investigate pollution hotspots and preserve spatial evidence for environmental assessment and follow-up.
The hardware, platform integration and AIRINS.ai stay connected from mission setup to the final operational record.
01
Configure
Select the sensing modules and platform for the application.
02
Deploy
Operate from an aerial, dock-based or ground platform.
03
Analyse
Review georeferenced measurements and spatial patterns.
04
Act
Export reports, data and mission records for follow-up.
Deployment options
Bring the same sensing logic to different platforms.
Choose around coverage, automation, access and the aircraft or vehicle already available to the operating team.
Repeatable autonomous coverage
Build routine measurement into a dock-based operation.
Suitable where the same area or route must be revisited consistently with minimal on-site setup.
DJI Pilot 2 and FlightHub 2 workflow
Higher-payload integration
Carry one or two Sniffer4D units for more demanding missions.
Use the larger platform for flexible payload configuration, including a dual-Sniffer setup when the application requires it.
Single- or dual-Sniffer configuration
Compact enterprise fleets
Add gas measurement to aircraft already used by field teams.
Integrated configurations support common DJI enterprise platforms used for inspection and mapping.
Matrice 4E / 4T / 30 / 30T
Platform Agnostic Integration Kit
Use Sniffer4D beyond the DJI ecosystem.
The Sniffer4D Platform Agnostic Integration Kit provides its own GNSS and power-management system. The host platform needs to provide 12–60 V DC power.
Own GNSS · own power management · 12–60 V DC input
Ground access
Measure where aerial operation is unsuitable or unnecessary.
Bring the same sensing and AIRINS.ai workflow onto quadruped robots or ground vehicles for route-based and close-access work.
Quadruped and vehicle configurations
Sniffer4D configurations
Choose multi-gas flexibility or dedicated methane sensing.
Both configurations use the same connected deployment and AIRINS.ai workflow, while the sensing architecture is selected around the application.
Configurable sensing
Sniffer4D Nano 2 Plus Multi-Gas
Five internal slots support sensing modules selected for environmental, industrial or emergency applications.
This table applies only to Sniffer4D Nano 2 Plus Multi-Gas. Sniffer4D Nano 2 Plus Methane uses a separate dedicated sensing architecture; its specifications are shown in the configuration card above.
5 slots totalMulti-Gas capacity
1 slot eachMost modules
Uses all 5TSP / PM100
Sensor module
Slots required
Sensing principle
Linear range
Limit of detection
Display resolution
PM1.0 / PM2.5 / PM10
1
Light scattering
5–1,000 µg/m³
5 µg/m³
1 µg/m³
O₃ + NO₂
1
Electrochemistry
0–11 ppm
10 ppb
1 ppb
NO₂
1
Electrochemistry
0–11 ppm
10 ppb
1 ppb
CO
1
Electrochemistry
0–11 ppm
0.05 ppm
0.005 ppm
TVOC
1
PID
0–50 ppm (isobutylene)
0.02 ppm
0.01 ppm
H₂S
1
Electrochemistry
0–90 ppm
0.03 ppm
0.01 ppm
NH₃
1
Electrochemistry
0–100 ppm
1 ppm
0.1 ppm
Odour indicationH₂S-equivalent; indicative, not olfactometric
1
Electrochemistry
0–10 ppm H₂S-eq.
0.1 ppm H₂S-eq.
0.01 ppm H₂S-eq.
TSP / PM100
5
Light scattering
30–3,000 µg/m³
50 µg/m³
1 µg/m³
SO₂
1
Electrochemistry
0–15 ppm
0.03 ppm
0.005 ppm
HCHO
1
Electrochemistry
0–100 ppm
1 ppm
0.1 ppm
High-range combustible hydrocarbonsResponds to methane and other alkanes; readings reported as CH₄-equivalent.
1
NDIR
0–5% vol CH₄-eq.
—
0.01% vol CH₄-eq. For high-concentration indication only
Need an exact combination?
Tell AIRINS the target gases, expected range, platform and operating environment. We will recommend a compatible configuration.
Select an output to see how AIRINS.ai carries a Sniffer4D mission into review, reporting and follow-up.
Live mission view
Measurements connected to position
Review current readings in their geographic and mission context while the operation is underway.
Threshold exceededCH₄ 12.8 ppmDJI Pilot 2 live warning
Configurable concentration threshold
See the warning during flight
Set a concentration threshold for the mission. When it is exceeded, a visual alarm appears in the DJI Pilot 2 app so the operator can respond immediately.
3D concentration distribution
Point, grid and interpolation views
Move between two-dimensional and three-dimensional representations to understand spatial concentration patterns.
Sniffer4D mission reportLocation · time · area · parameters
PDF / editable DOCX
Ready to share and continue working with
Generate a structured mission summary containing context, measurement distributions and selected visual evidence.
CSVGeoJSONShapefileAnimationData for existing workflows
Use results outside AIRINS.ai
Export tabular, GIS-ready and animated outputs for internal analysis, mapping systems and briefings.
01North boundary surveyCompleted · 4 parameters
02Process-area follow-upCompleted · methane
03Routine monthly routeScheduled
Keep repeat work organised
Review completed missions and preserve a consistent record for recurring surveys and follow-up work.
From the field
Evidence across different operating jobs.
See how Sniffer4D connects the deployed configuration, measurement context and practical result across environmental, industrial and methane-survey work.
01Indonesia
With Halo Robotics
Flare-stack inspection in Indonesia
Two sensing payloads surveyed different flare-stack sections for an oil and gas operator.
Sniffer4D is supplied through a one-time purchase. AIRINS quotes the configuration after confirming the required sensing modules, platform and integration accessories.
01 · Sensor configuration
Select the measurements the job requires.
The price is determined by the chosen internal sensing modules and whether the configuration is multi-gas or dedicated to methane.
02 · Platform integration
Match the system to the deployment.
The quotation includes the applicable DJI or platform-agnostic integration kit, mounting and any selected field accessories.
One-time purchase; exact quotation by configuration
Standard one-year product warranty included
AIRINS.ai Private Deployment available as a separately priced add-on; first-year support and updates included, with annual renewal thereafter
Shipping, taxes, duties and local installation excluded
Distributor pricing may reflect local costs
Standard configurations normally ship within one week after payment
01 Discuss the configuration
02 Receive quotation and invoice
03 Pay and prepare shipment
Frequently asked questions
Choose around the mission, not only the sensor list.
Configuration depends on the target gases, aircraft or vehicle, operating environment and required output.
How do Sniffer4D and MetScan differ?
Sniffer4D provides in-situ gas measurements for spatial mapping and application-specific assessments. MetScan focuses on remote methane screening and source localisation, with SRQ available through eligible configurations. AIRINS recommends the sensing approach around the measurement objective, access conditions and required output.
Can Sniffer4D be integrated with non-DJI UAVs?
Yes. The Sniffer4D Platform Agnostic Integration Kit provides its own GNSS and power-management system. The host platform needs to provide 12–60 V DC power.
Can one aircraft carry two Sniffer4D units?
DJI Matrice 400 and DJI Matrice 350 / 300 configurations can include a dual-Sniffer setup when the application and aircraft configuration require it.
How are sensing modules selected?
AIRINS selects compatible module combinations around target gases, expected concentration ranges, environmental conditions and the available internal slots.
What can be delivered after a mission?
AIRINS.ai supports georeferenced measurements, 2D and 3D visualisations, reports, mission records and common GIS or tabular exports.
What is the high-range combustible hydrocarbon module for?
It adds a one-slot, high-range CH₄-equivalent sensor to a HAZMAT Multi-Gas configuration. The other four slots are selected for the incident, commonly covering TVOC, CO, H₂S, SO₂ or NO₂. It is intended only to indicate high combustible-hydrocarbon concentrations—not to measure ambient methane or GHG emissions—and does not replace certified personal or fixed-area gas-safety instruments.
Can Sniffer4D deliver flare-efficiency and marine methane-slip assessments?
Yes. AIRINS provides validated, application-specific measurement and analysis workflows for both tasks. The sensing configuration, sampling procedure, assessment method and deliverables are agreed for the selected application.
Configure the field workflow
Tell us what you need to measure and where.
Share the target gases, platform, operating environment and required output. AIRINS will recommend a Sniffer4D configuration.